SC(B)H15-M series amorphous alloy dry-type transformer technical parameters

06-27 2025 | By:

SC(B)H15-M series amorphous alloy dry-type transformer

How much does Dry type transformer cost?

How much does Dry type transformer cost?

Amorphous alloy uses an advanced ultra-rapid cooling technology to spray liquid melts such as iron, cobalt, boron, and silicon onto a chassis with a very high rotation speed and rapidly cool them to form a thin strip of 0.02mm-0.04mm. It has excellent soft-tie performance, corrosion resistance, wear resistance and high resistivity.

Compared with cold-rolled grain-oriented silicon steel sheets, amorphous alloy cores for transformers have the following advantages:

1. Amorphous alloy materials do not have a crystal structure and are isotropic soft magnetic materials with low magnetization power.

2. There are no structural defects that hinder the movement of magnetic domain walls, and their hysteresis loss is smaller than that of silicon steel sheets.

3. The resistivity is extremely high, 3-6 times that of silicon steel sheets, and its eddy current loss is greatly reduced, with unit eddy current loss being only 20%-30% of that of silicon steel sheets. SCBH15 series amorphous alloy dry-type transformers are a new type of low-loss energy-saving distribution transformers. This product combines the technical advantages of amorphous alloy transformers and traditional epoxy resin cast dry-type transformers, and adopts a new structural form to make it have the outstanding characteristics of low loss, especially no-load loss, which is 70% lower than that of conventional 10 series dry-type transformers. This product also has the characteristics of compact structure, beautiful appearance, low noise, low temperature rise, strong overload capacity, stable electrical performance, and easy maintenance.

SC(B)H15-M series amorphous alloy dry-type transformer use conditions

SC(B)H15-M series amorphous alloy dry-type transformer

SC(B)H15-M series amorphous alloy dry-type transformer

1. Altitude not more than 1000m (special design is required when it is greater than 1000m).
2. Ambient temperature: maximum temperature +40℃, average temperature of the hottest month +30℃; minimum temperature -25℃, average temperature of the hottest year +20℃.
3. The waveform of the power supply voltage is similar to a sine wave; the three-phase power supply voltage is roughly symmetrical.
4. Installed indoors, the use environment is not obviously dirty.

SC(B)H15-M series amorphous alloy dry-type transformer product features

SCBH15 series amorphous alloy dry-type transformer has the advantages of low no-load loss, oil-free, flame retardant and self-extinguishing, moisture-resistant and maintenance-free. Now all places where ordinary dry-type transformers are applicable are suitable for amorphous alloy transformers (including airports, stations, urban subways, high-rise buildings and power plants, etc.),
especially in places where flammable, explosive and power shortages are more suitable. The specific features are:
1. Low consumption and energy saving: It adopts isotropic soft magnetic conductive material, with low magnetization power, high resistivity and low eddy current loss. The no-load loss and no-load current of the core made of amorphous alloy material are very low, only 1/3 of silicon steel sheet. The no-load loss of the transformer is 75% lower than the value specified in GB/T10228. It can greatly reduce operating costs and achieve significant energy-saving effects.
2. Strong corrosion resistance: The amorphous alloy core is fully encapsulated by resin and high-temperature resistant silicone to effectively prevent rust and amorphous alloy fragments from falling off, thereby effectively protecting the core and coil.
3. Low noise: In order to reduce the operating noise of the product, a reasonable working magnetic density is selected during product design, the core and coil structure is improved during product processing, and special noise reduction materials are used. The product noise is much lower than the national standard JB/T10088 requirements.
4. Strong short-circuit resistance: The product adopts a three-phase three-column structure, and the core is protected by a frame structure around it, with a compact and reasonable structure.
5. Low temperature rise and long service life: The product has low temperature rise and strong heat dissipation capacity. It can operate at 150% rated load under forced air cooling conditions. Optional temperature control protection system with perfect performance can provide reliable guarantee for safe operation of transformer.

SC(B)H15-M series amorphous alloy dry-type transformer Parameter

Rated capacity (kVA) Voltagegroup Vector group Loss (W) No-load current(%) Impedance voltage (%) Weight (Kg) Boundary dimension (L×W×H,mm) Gauge
HV (kV) LV (kV) No-loadloss(W) Loadloss75℃ Longitudinal/transverse (mm)
100 11 10.5 10 6.3 6 0.4 Dyn11 130 1570 1.2 4 890 950×600×960 550×550
160 170 2130 1.1 1170 1220×600×1060 550×550
200 200 2530 1.0 1400 1270×710×1160 660×660
250 230 2760 1.0 1560 1350×760×1240 660×660
315 280 3470 0.9 1770 1370×870×1360 820×820
400 310 3990 0.8 2180 1460×870×1360 820×820
500 360 4880 0.8 2440 1490×870×1430 820×820
630 420 5880 0.7 2850 1760×1120×1490 1070×1070
630 410 5960 0.7 6 3015 1710×970×1450 1070×1070
800 480 6960 0.7 3430 1850×1120×1600 1070×1070
1000 550 8130 0.6 4050 1900×1120×1170 1070×1070
1250 650 9690 0.6 4690 2030×1120×1880 1070×1070
1600 760 11730 0.6 5610 2120×1120×1970 1070×1070
2000 1000 14450 0.5 5820 2120×1120×1990 1070×1070
2500 1200 17170 0.5 6730 2190×1120×2110 1070×1070