35KV SZ11 Type On-Load Tap-Changing Power Transformer

Rated voltage34.5/35/38kv
Rated capacity1MVA-31.5MVA
Application scenariosUrban and rural power distribution substations Industrial power supply systems Mining and metallurgical plants Wind and solar power stations Petrochemical and manufacturing facilities
Certifications & StandardsIEC 60076 GB 1094 ANSI / IEEE ISO 9001 CE

Product Overview

The 35KV SZ11 Type On-Load Tap-Changing Power Transformer is a high-efficiency oil-immersed power transformer designed for medium-voltage transmission and distribution systems. It features an advanced on-load tap changer (OLTC) that enables voltage regulation under load without interrupting power supply, ensuring stable grid operation and high power quality.

SZ11 transformers adopt low-loss core materials, optimized winding structure, and enhanced insulation systems, making them ideal for utility substations, industrial plants, renewable energy grids, and urban distribution networks.

Key Features

On-Load Tap-Changing Technology

  • Voltage adjustment without power interruption

  • Improves system voltage stability

  • Suitable for fluctuating load conditions

Energy-Saving Design

  • Low no-load loss and load loss

  • Meets national and international energy efficiency standards

  • Reduces long-term operating costs

Reliable Insulation System

  • High-quality oil-paper insulation

  • Strong thermal and dielectric performance

  • Long service life under continuous operation

Robust Mechanical Structure

  • Short-circuit resistance

  • Anti-vibration core clamping design

  • Suitable for harsh operating environments

Factory Testing

Each SZ11 transformer undergoes strict inspection and testing:

  • Winding resistance test

  • Voltage ratio and vector group test

  • No-load loss and current test

  • Load loss and impedance test

  • Partial discharge test

  • Oil dielectric strength test

35KV SZ11 Series On-Load-Tap-Changing Power Transformer(ONAN)

 

  Type RatedCapachy
(kVA)
Voltage comblnation Connection
symbol
NO-boad Loss
(kW)
load Loss
(KW)
NO-load
Current
(%)
Short-circuit
Impedance
(%)
HV Taping Range ofHN LV
SZ11-1000/35 1000 35 ±3×2.5% 0.4 Yyno 1.34 11.4 1 6.5
SZ11-1250/35 1250 1.57 13.4 1
SZ11-1600/35 1600 1.91 16.1 0.9
SZ11-2000/35 2000 2.24 19.1 0.9
SZ11-1600/35 1600 35 ±3×2.5%
±4×2.5%
6.3
10.5
Ydll 1.91 16.2 0.9
SZ11-2000/35 2000 2.3 19.1 0.9
SZ11-2500/35 2500 2.72 20.5 0.7
SZ11-3150/35 3150 35
38.5
3.23 24.6 0.7 7
SZ11-4000/35 4000 3.87 29 0.6
SZ11-5000/35 5000 4.64 34 0.6
SZ11-6300/35 6300 5.63 36.6 0.4 7.5
SZ11-8000/35 8000 6
6.3
10.5
11
Yndll 7.87 40.4 0.4
SZ11-10000/35 10000 9.28 47.8 0.4
SZ11-12500/35 12500 10.94 56.5 0.3 8
SZ11-16000/35 16000 13.17 69 0.3
SZ11-20000/35 20000 15.57 83.2 0.2
SZ11-25000/35 25000 18.6 98.2 0.2
SZ11-31500/35 31500 21.9 116.6 0.2
Type RaedCapachy
(KVA)
(kg)Waight    (mm)Overall Dimension (mm)
Track Spacing
OiL Total (L) (W) (H)
SZ11-1000/35 1000 1510 4825 2855 1600 2580 820×820
SZ11-1250/35 1250 1575 5450 2890 1750 2605 1070×1070
SZ11-1600/35 1600 1650 6250 2935 1900 2620 1070×1070
SZ11-2000/35 2000 1770 7000 3050 2100 2645 1070×1070
SZ11-1600/35 1600 1665 6350 2890 1950 2700 1070×1070
SZ11-2000/35 2000 1775 7000 3050 2000 2800 1070×1070
SZ11-2500/35 2500 2100 8000 3200 2100 2850 1070×1070
SZ11-3150/35 3150 2450 9425 3500 2960 2850 1070×1275
SZ11-4000/35 4000 2650 10650 3600 3010 2965 1070×1275
SZ11-5000/35 5000 2900 12250 3700 3200 3070 1070×1275
SZ11-6300/35 6300 3490 14350 3900 3380 3215 1070×1275
SZ11-8000/35 8000 4530 18150 4240 3490 3295 1070×1475
SZ11-10000/35 10000 5050 20400 4435 3460 3400 1070×1475
SZ11-12500/35 12500 6000 23850 4565 3700 3850 1070×1475
SZ11-16000/35 16000 6640 27800 4815 4300 3950 1070×1475
SZ11-20000/35 20000 8050 32800 5200 4425 4100 1070×1475
SZ11-25000/35 25000 8500 39500 5080 4550 4150 1475×1475
SZ11-31500/35 31500 9485 43500 5190 4700 4300 1475×1475

35kV S11 Series Off-Circuit-Tap-Changing Distribution Transformer

Type Rated Capacky
(kVA)
Votage combination Connection
symbol
NO-oad Loss
(kW)
load Loss
(kW)
NO-load
Current
(%)
Short-circuit
Impedance
(%)
HV Tapping Range ofHV (KV)
LV
S11-50/35 50 35
38.5
±5% 0.4 Yyno
Dyn11
0.17 1.15/1.21 2 6.5
S11-100/35 100 0.23 1.92/2.01 1.9
S11-125/35 125 0.27 2.26/2.38 1.8
S11-160/35 160 0.29 2.68/2.82 1.7
S11-200/35 200 0.34 3.15/3.33 1.6
S11-250/35 250 0.41 3.74/3.95 1.5
S11-315/35 315 0.49 4.51/4.76 1.4
S11-400/35 400 0.58 5.44/5.75 1.13
S11-500/35 500 0.69 6.55/6.92 1.2
S11-630/35 630 0.83 7.82 1.1
S11-800/35 800 0.98 9.35 0.9
S11-1000/35 1000 1.15 11.5 0.8
S11-1250/35 1250 1.41 13.9 0.7
S11-1600/35 1600 1.7 16.6 0.6
Type Ratsd Capachy
(kVA)
  (kg〕Waight    (mm)Overall Dimension ( mm)
Track Spacing
OiL Total (L) (W) (H)
S11-50/35 50 280 775 1150 900 1800 550×550
S11-100/35 100 390 1150 1210 950 1880 660×660
S11-125/35 125 425 1225 1320 1120 1960 660×660
S11-160/35 160 475 1395 1400 1140 1980 660×660
S11-200/35 200 510 1510 1420 1160 2000 660×660
S11-250/35 250 555 1670 1480 1200 2050 660×660
S11-315/35 315 585 1980 1730 1180 2100 660×660
S11-400/35 400 630 2200 2100 1155 2300 660×660
S11-500/35 500 710 2495 2100 1220 2170 820×820
S11-630/35 630 800 3450 2150 1250 2250 820×820
S11-800/35 800 930 3900 2300 1310 2350 820×820
S11-1000/35 1000 1050 4550 2480 1360 2450 820×820
S11-1250/35 1250 1200 4900 2500 1420 2585 820×820
S11-1600/35 1600 1265 5500 2650 1750 2605 1070×1070

Related Content

Case

 